Document Page: First | Prev | Next | All | Image | This Release | Search
File: 090496_jul96_decls31_0001.txt
Subject: WATER TESTING
Box ID: BX000420
Document Number: 48
Folder Title: HISTORIANS BACKGROUND MATERIAL FILES - G3 NBC MIS 2 OF 4
Folder Seq #: 3
Unit: ARCENT
Parent Organzation: CENTCOM
UNCLASSIFIED
PRIORITY -TDRX @74 1351
PARSTYUW RUDCEKM3129 0341351 RUDCEKM.
ZNY
P 291638Z JAN 91
FM COMUSARCENT mnrN//03/SURB//
TO RUFTFZA/PRCENT SPT CMD//CS//
INFO RHsrMCU/CDRUSARCENT CP//SURS/12TH AM FWD//
RUDCEKM/CDR ARCENT MEDCOM (PROV)//
RHSIMCU/CDRUSARCENTCP//JUMP CP KKMC//SURG//
BT
SUBS: WATER TESTING
A. REFERENCE MEMORANDUM HOs ARCENT MCP (AFRD-88-FWD) DATED 26 SAN
91, SAB.
1. (U) WE HAVE THE CAPABILITY TO TEST WATER SPECIMENS FOR HE
METALS. WE WILL TEST FOR LEAD, MERCURY9 CADIUM AND ARSENIC.
SERVICE CAN BE DONE DAILY. SPECIMENS ARRIVING BEFORE 140e HOU
WILL BE RUN THAT DAY. NEXT DAY SERVICE WILL BE PROVIDED FOR
SPECIMENS ARRIVING AFTER THAT HOUR. REBULTS CAN BE TRANSMITTED
TELEPHONICALLY OR BY HARD COPY.
2. TESTING FOR THALLIUM AND PETROLEUM PRODUCTS ARE A
POSSIBILITY ONCE CERTAIN MINOR PIECES OF EQUIPMENT AND CHEMICAL
STANDARDS ARE OBTAINED. USPEUR AND USAEHA HAVE BEEN CONTACTED.
ANSWERS EXPECTED WITHIN 48 HOURS.
3. (U) PROCEDURES: SAMPLES ARE TO BE COLLECTED IN PLASTIC
PAGE 02 RUDCEKM3129
CONTAINERS PROVIDED. SAMPLING POINT IS TO BE PURSED FOR FIVE (5)
MINUTES PRIOR TO COLLECTION. CONTAINERS SHOULD BE FILLED TWO-THIRDS
TO THREE-FOURTHS AND SECURELY FASTENED. THE PLASTIC CONTAINERS ARE
NUMBERED 001 TO 100. INDIVIDUAL COLLECTINS SPECIMEN MUST NOTE DATE
/TIME AND LOCATION. SAMPLES ARE TO BE TRANSPORTED EXPEDITIOUSLY TO
WATER LABORATORY IETH AM TERM LOCATED AT OLD MODA HOSPITAL KKMC
(POC MAJ DESWARTE COMM 787-1777 EXT 2180/2182). SAMPLES SHOULD BE
PACKED UPRIGHT IN AN INSULATED CONTAINERs PREFERABLY IN ICE. SAMPLE
WILL BE TREATED WITH PRESERVATIVE AND TAKEN TO KKMC AIRPORT FOR
TRANSPORTATION TO RIYADH. ONCE IN RIYADH, 12TH AM TEAM LIAISON WILL
TAC 9-7804-692/580).
4. (U) COORDINATION FOR TIMELY TRANSPORTATION TO RIYADH REQUEBTED.
ALSO REQUESTED A POC FOR RESULTS AT KKMC.
5. (U) POC IS COL E. PEARLMAN, ARCENT SURGEONIS OFFICE PREVENTIVE
MEDICINE CONSULTANT9 COMM 498-0613/TAC 9-7804-69a-580.
DECL (ORDR)
BT DECLASSIFIED
#3129 ON: 26 AUG 96
BY: SEC ARMY (DAMH) UNDER SEC
UNCLASSIFIED 3.4 EO 12958
PRIORITY