Document Page: First | Prev | Next | All | Image | This Release | Search
File: 970101_jul96_decls1_0002.txt
Subject: M12A6 DECONTAMINATION APPARATUS SERVICEABILITY OPERATION DS
Unit: ARCENT
Parent Organization: CENTCOM
Box ID: BX000401
Folder Title: TACTICAL OPERATIONS CENTER LOGS - MSG FILE LOGS 30 SEP 90
Document Number: 8
Folder Seq #: 1
uuuuuuuuuuuuuuuu
U UNCLASSIFIED U
uuuuuuuuuuuuuuuu
RECEIVED AT 17:08 Z
PRIORITY RUDCHAA COMUSARCENT MAIN//AFRD-DTO//
1. REF A AND B ARE RETRANSMITTED AS FOLLOWS: QUOTE
01. THIS IS AMCCOM MAINTENANCE ADVISORY MESSAGE 90-20.
2. FOR DESERT SHIELD OPERATIONS, HOT WATER CAUSES THE DECONTAMINANT
USED WITH THE M12AI TO BE MORE EFFECTIVE: MAKE SURE YOUR M2 WATER
HEATER WORKS.
3. HOWEVER, IF YOUR M2 WATER HEATER IS DEADLINED TEMPORARILY, AS
DEPICTED IN TM3-4230-209-10, THE M12Al'S PRIMARY MISSION--MIXINO AND
APPLYING STB SLURRY FOR DECONTAMINATION--CAN STILL BE ACCOMPLISHED BY
PAGE 02 RUDCHAA3367 UNCLAS
PERFORMING THE STEPS WHICH FOLLOW: (1) -AT STATION ONE, USE TWICE AS
MUCH LIQUID DETERGENT THAN IS NORMAL BECAUSE OF COOLER WATER
TEMPERATURES; (2) AT STATION TWO, SCRUB TWICE AS LONS TO ALLOW FOR
MORE REACTION TIME BECAUSE OF COOLER EQUIPMENT SURFACES% (3) LIMIT
DECONTAMINATING AGENT USAGE TO ONLY--REPEAT, ONLY--STS; (4) USE
ANTISET COMPOUND, NSN 6e5O,OO,656,0926, BECAUSE OF COOLER WATER
TEMPERATURES; (5) ONLY USE THE M12AI ABOVE 35 DEGREES% (6) BECAUSE
OF MORE RAPID COOLING DURING NIGHT OPERATIONS, ALLOW 45 MINUTES FOR
THE DECONTAMINANT TO REACT WITH THE CHEMICAL AGENT; (7) AT STATION
FOUR, MORE WATER WILL LIKELY BE REQUIRED TO REMOVE CONTAMINATION;
WATER CONSERVATION IN THIS PARTICULAR GEOGRAPHICAL AREA CAN BE
CRITICAL. KEEP THE M2 HEATERS WORKING!
4. DESERT SHIELD ARMY UNITS UNABLE TO FIX INOPERABLE M2 WATER
HEATERS OR OTHER COMPONENTS OF THE M12Al DECON APPARATUSES, SHOULD
EK ADVICE FROM THE LOGISTICS ASSISTANCE REPRESENTATIVES (LARS)
ALREADY DEPLOYED 1N-COUNTRY.
S. ALL OTHER U.S. ARMY ELEMENTS ARE ADVISED TO FOLLOW NORMAL
MAINTENANCE DEADLININS POLICIES AND GUIDANCE AND TO SEEK ADVICE FROM
LOCAL LARS IN CASE FUTURE DEPLOYMENTS ARE REQUIRED TO AID OPERATION
DESERT SHIELD.
PAGE 03 RUDCHAA3367 UNCLAS
6. THIS MAINTENANCE ADVISORY MESSAGE WAS COORDINATED WITH THE
CHEMICAL SCHOOL$ FT MCCLELLAN, AL AND SHOULD BE APPLIED UNTIL FURTHER
NOTICE.
7. THE POC THIS OFFICE 18 MR. JAMES E. BLACKISTON, DSN 584-3681 OR
COMMERICIAL (301) 671-36Sl.
S. AMCCOM WE PROVIDE THE FIRE POWER."END QUOTE
2. THE POC LTC MANLEY, USARCENT MAIN, 03-OPS/NBC, COMM:
011-966-1-478-1264.
BT
Document Page: First | Prev | Next | All | Image | This Release | Search
Document 2 f:/Week-29/BX000401/TACTICAL OPERATIONS CENTER LOGS - MSG FILE LOGS 30 SEP 90/m12a6 decontamination apparatus serviceability o:12269616083214
Control Fields 17
File Room = jul96_declassified
File Cabinet = Week-29
Box ID = BX000401
Unit = ARCENT
Parent Organization = CENTCOM
Folder Title = TACTICAL OPERATIONS CENTER LOGS - MSG FILE LOGS 30 SEP 90
Folder Seq # = 1
Subject = M12A6 DECONTAMINATION APPARATUS SERVICEABILITY O
Document Seq # = 8
Document Date =
Scan Date =
Queued for Declassification = 01-JAN-1980
Short Term Referral = 01-JAN-1980
Long Term Referral = 01-JAN-1980
Permanent Referral = 01-JAN-1980
Non-Health Related Document = 01-JAN-1980
Declassified = 26-DEC-1996