Subject: MATERIAL RELEASE REQ FOR CALL FWD OF CHEMICAL AGENT MONITOR     

Unit: ARCENT      

Parent Organization: CENTCOM     

Box ID: BX000430

Folder Title: TACTICAL OP CTR LOGS - MSG FILE LOG 1-2 JAN 91                                                  

Document Number:         12

Folder SEQ  #:          1




                                  uuuuuuuuuuuuuuuu
                                  U UNCLASSIFIED U
                                  uuuuuuuuuuuuuuuu






                                RECEIVED AT 18:58 Z


   PRIORITY          RULNEAA PMNBC DEF SYS APB MD//AMCPM-NN//

   SUPPORT PLANNED CAM FIELDINGS.
   B. AN INSTRUCTION SHEET FOR USE OF THE BATTERY PACK IS IN
   PREPARATION. THE INSTRUCTION SHEET WILL BE ISSUED WITH THE BATTERY
   PACK.





   PAGE 03 RULNEAA0232 UNCLAS
   C. TRAINING WILL BE CONDUCTED VIA THE IN-COUNTRY CAM MOBILE TRAINING
   TEAM (MTT).
   D. LIMITATIONS.
   (1) USE OF THE BATTERY PACK SHOULD BE LIMITED TO TRAINING ONLY. THE
   USER INSTRUCTIONS WILL STATE SPECIFICALLY THAT THE DEVICE IS FOR
   TRAINING ONLY.
   (2) BELOW 60 DEGREES F, "D" CELLS HAVE A REDUCED OPERATIONAL LIFE.
   THESE LIMITATIONS WILL BE OUTLINED IN THE USER INSTRUCTION SHEET AND
   PROVIDED TO CENTCOM.
   E. USE OF THE TRAINING BATTERY PACK IN A NBC ENVIRONMENT IS NOT
   RECOMMENDED. THE PRIMARY RISK OF USING THE CAM TRAINING BATTERY PACK
   IN AN NBC ENVIRONMENT IS THE POTENTIAL OF DAMAGE TO THE CAM. THE
   FOLLOWING PROCEDURES WILL REDUCE THE POTENTIAL OF DAMAGING THE CAM.
   (1) IF THE TRAINING BATTERY PACK IS CONTAMINATED THE OPERATOR SHOULD
   NOT ATTEMPT TO DECONTAMINATE THE PACK. THE PACK SHOULD BE REMOVED AND
   DISPOSED OF. AFTER REPLACING THE BATTERY CAP ASSEMBLY, THE CAM MAY BE
   DECOMTAMINATED IAW TM 3-6665-327-13&P.
   (2) IF THE OPERATOR REPLACES THE NOZZLE PROTECTIVE CAP ASSEMBLY
   DURING OPERATOR TROUBLESHOOTING PROCEDURES IAW TM 3-6665-327-13&P THE
   OPERATOR SHOULD ALSO REPLACE THE TRAINING BATTERY PACK WITH THE





   PAGE 04 RULNEAA0232 UNCLAS
   STANDARD CAM BATTERY OR A NEW BATTERY PACK.
   (F) IF THE OPERATOR OBSERVES AN INTERMITTENT BATTERY LOW (BL)
   INDICATOR, REPLACE BATTERIES IMMEDIATELY. DO NOT ATTEMPT TO CONTINUE
   TO OPERATE THE CAM, EVEN IF THE BL INDICATOR TURNS OFF TEMPORARILY.
   5. ISSUES.
   A. TESTING. LIMITED TESTING HAS BEEN CONDUCTED WITH EARLY
LEM WAS IDENTIFIED WHICH HAS SUBSEQUENTLY BEEN
   FIXED THROUGH CHANGES IN THE DESIGN. THE BATTERY PACK IS ONLY

                                     02 OF 03
                                   uuuuuuuuuuuuuuuu
                                   U UNCLASSIFIED U
                                   uuuuuuuuuuuuuuuu

Document Page: First | Prev | Next | All | Image | This Release | Search


Document 3 f:/Week-29/BX000430/TACTICAL OP CTR LOGS - MSG FILE LOG 1-2 JAN 91/material release req for call fwd of chemical ag:09209615581323
Control Fields 17
File Room = jul96_declassified
File Cabinet = Week-29
Box ID = BX000430
Unit = ARCENT
Parent Organization = CENTCOM
Folder Title = TACTICAL OP CTR LOGS - MSG FILE LOG 1-2 JAN 91
Folder Seq # = 1
Subject = MATERIAL RELEASE REQ FOR CALL FWD OF CHEMICAL AG
Document Seq # = 23
Document Date =
Scan Date =
Queued for Declassification = 01-JAN-1980
Short Term Referral = 01-JAN-1980
Long Term Referral = 01-JAN-1980
Permanent Referral = 01-JAN-1980
Non-Health Related Document = 01-JAN-1980
Declassified = 20-SEP-1996